RJ-10多功(gong)能(neng)血液溶(rong)漿(jiang)機產(chan)品說(shuo)明:
針對醫(yi)院血庫(ku)需(xu)求(qiu),我廠(chang)特(te)自行(xing)研制了(le)新(xin)型多功(gong)能(neng)溶漿(jiang)機,該(gai)機采用數(shu)碼(ma)顯(xian)示(shi),電(dian)腦控(kong)溫,可(ke)根據(ju)不(bu)同(tong)的(de)需(xu)求(qiu),任(ren)意設定(ding)溫度,水(shui)溫差不(bu)大(da)於(yu)±1℃,配套(tao)安(an)裝(zhuang)了(le)自動(dong)搖擺(bai)系統(tong),可(ke)自動(dong)調控(kong)頻(pin)率(lv),特(te)別(bie)是熔(rong)化(hua)血漿,熔(rong)化(hua)和(he)擺(bai)動(dong)同時(shi)進行(xing),數(shu)分(fen)鐘取(qu)出即可(ke)使(shi)用。減少(shao)了(le)工(gong)序(xu),為(wei)搶(qiang)救(jiu)病人節(jie)省(sheng)了(le)時(shi)間(jian),方便了(le)醫(yi)務工(gong)作(zuo)者(zhe),是血庫(ku)理想(xiang)的(de)配(pei)套(tao)工(gong)具。
RJ-10多功(gong)能(neng)血液溶(rong)漿(jiang)機註(zhu)意事項(xiang) :
1.平時(shi)設定(ding)水溫,可(ke)長期開(kai)機,用(yong)時(shi)將(jiang)擺(bai)幅(fu)開關(guan)打開,設定(ding)頻(pin)率(lv),自動(dong)搖擺(bai),用(yong)完關(guan)掉搖擺(bai)開(kai)關,節(jie)約用電(dian),減(jian)少機械磨損。
2.使(shi)用前(qian)壹定(ding)要將(jiang)水(shui)加(jia)到水位線,切(qie)勿幹(gan)燒(shao),以保護(hu)加(jia)熱管。隨(sui)著開(kai)機時(shi)間(jian)的(de)不(bu)斷(duan)增(zeng)長,水(shui)箱的(de)水(shui)回逐(zhu)漸(jian)蒸(zheng)發(fa),請隨(sui)時(shi)檢(jian)查水(shui)位(加(jia)水(shui)換(huan)水)。確(que)保機器(qi)正(zheng)常(chang)運(yun)轉(zhuan)。
3.設定(ding)溫度:按SET鍵(jian)可設定(ding)或查看(kan)溫度設定(ding)點(dian)。按壹(yi)下SET鍵管字(zi)符開(kai)始(shi)閃動(dong),表示(shi)儀(yi)表(biao)進入(ru)設定(ding)狀態(tai),按△鍵(jian)設定(ding)值增(zeng)加(jia),按△或▽鍵數(shu)據(ju)會(hui)快速(su)變動(dong),再(zai)壹次按SET鍵(jian)儀表回到正(zheng)常(chang)工(gong)作(zuo)狀(zhuang)態(tai)溫度設定(ding)完畢(bi),開(kai)始(shi)加(jia)熱指示(shi)燈(deng)亮(liang)。
4.提(ti)前(qian)設置:按SET鍵(jian)3秒儀(yi)表進入(ru)內(nei)層(ceng)參數(shu)設定(ding)狀態(tai)。*個(ge) 出現並閃動(dong)的(de)參數(shu)為(wei) 即(ji)停止的(de)提(ti)前(qian)量,提(ti)前(qian)量參數(shu)要(yao)慎(shen)重調(tiao)整,為(wei)減(jian)少溫度過(guo)沖(chong),儀表(biao)控(kong)制(zhi)加(jia)熱輸(shu)出(chu)時(shi)會(hui)提(ti)前(qian)截止(zhi)加(jia)熱,當(dang)溫度下跌到提(ti)前(qian)量以下時(shi)又(you)開(kai)始(shi)加(jia)熱,在設定(ding)值與(yu)提(ti)前(qian)量範圍(wei)內(nei)輸(shu)出(chu)(繼(ji)電(dian)器(qi))是不(bu)會(hui)工(gong)作(zuo)的(de),這(zhe)樣(yang)可(ke)減(jian)少(shao)繼電(dian)器(qi)動(dong)作(zuo)次數(shu)以延長繼(ji)電(dian)器(qi)使(shi)用壽(shou)命。例(li):若設定(ding)值為(wei)50.0℃,提(ti)前(qian)量為(wei)0.5,儀(yi)表控(kong)制(zhi)加(jia)熱到49.5.0時(shi)繼(ji)電(dian)器(qi)釋(shi)放(fang),溫度下跌到50.0℃-0.5℃=49.5℃時(shi)繼(ji)電(dian)器(qi)又吸(xi)合。提(ti)前(qian)量越大(da)繼(ji)電(dian)器(qi)動(dong)作(zuo)次數(shu)越(yue)少(shao),提(ti)前(qian)量過大(da)會(hui)降(jiang)低控(kong)制(zhi)精度。調(tiao)整好提(ti)前(qian)量參數(shu)後(hou)按SET鍵(jian)3秒儀(yi)表回到工(gong)作(zuo)狀(zhuang)態(tai)。﹙註(zhu)意(yi):提(ti)前(qian)設置是為(wei)防(fang)止加(jia)熱停止(zhi)後(hou)溫沖(chong)過高(gao)而專門(men)設置的(de),壹(yi)般情(qing)況下不(bu)需(xu)要(yao)修改(gai)﹚。
5.誤差的(de)修正(zheng):在確(que)認儀表(biao)顯(xian)示(shi)的(de)值(zhi)不(bu)是(shi)正(zheng)確(que)的(de)測(ce)量值時(shi)可(ke)對(dui)顯(xian)示(shi)值(zhi)進行(xing)修正(zheng)。按SET鍵(jian)3秒進入(ru)儀(yi)表(biao)深層菜單(dan),*個出現(xian)並(bing)閃動(dong)的(de)參數(shu) 為(wei)E00即(ji)提(ti)前(qian)量,再(zai)按壹(yi)次SET鍵(jian)出(chu)現閃動(dong)的(de)參數(shu)即(ji)誤差修正(zheng)參數(shu),配(pei)合(he)△或▽鍵可(ke)修改(gai)此(ci)參數(shu)。誤差的(de)修正(zheng)範圍確(que)的(de)儀(yi)表(biao)修正(zheng)至不(bu)正(zheng)確(que)。為(wei)-9.9℃到+9.9℃,修正(zheng)完後(hou)再(zai)按壹(yi)下SET鍵退出。儀(yi)表(biao)出廠(chang)時(shi)修正(zheng)值為(wei)0.0。